logo
SCreate Dala Technology Co., Ltd.
SCreate Dala Technology Co., Ltd.
producten
Thuis /

producten

Flat Wire Single Axis Laser Micrometer Diameter Lump And Neck Measuring

Productgegevens

Plaats van herkomst: CHINA

Merknaam: Screate DALA

Modelnummer: TL-2000's

Betaling en verzendvoorwaarden

Min. bestelaantal: Bespreekbaar

Prijs: negotiable

Verpakking Details: Standaardverpakking, zoals de klant vereist

Levertijd: 7 - 15 werkdagen

Betalingscondities: T/T, enz.

Vind de beste prijs
Contact opnemen
Specificaties
Markeren:

Single Axis Laser Micrometer Diameter

,

Lump Neck Measuring Micrometer Diameter

Metingsgegevens:
klont en nek of diameter
Sollicitatie:
Platte draad, ronde draad
Meting:
0,02 ~ 6 mm en 0,2 ~ 25 mm
Herhaalbaarheid:
± 0,03um
Nauwkeurigheid:
± 0,5um
Maat:
224.6*36*62mm
Werkende energiebron:
24VDC ± 5%, max. 30W
Mededeling:
Wifi, rs485 Modbus rtu
Metingsgegevens:
klont en nek of diameter
Sollicitatie:
Platte draad, ronde draad
Meting:
0,02 ~ 6 mm en 0,2 ~ 25 mm
Herhaalbaarheid:
± 0,03um
Nauwkeurigheid:
± 0,5um
Maat:
224.6*36*62mm
Werkende energiebron:
24VDC ± 5%, max. 30W
Mededeling:
Wifi, rs485 Modbus rtu
Beschrijving
Flat Wire Single Axis Laser Micrometer Diameter Lump And Neck Measuring

High Impact Resistance,Strong adaptability to temperature change

 

Unique mechanical design enables the device with an impact resistance of 10G/6ms and vibration resistance of 10-55Hz/1.5mm in XYZ for 2 hours.
Individual temperature compensation technology enables the device measurement results not to be afected by temperature change*.
*The measurement diameter change <0.00lmm when temperature change is 40'℃ if the object diameter is 10mm.
Flat Wire Single Axis Laser Micrometer Diameter Lump And Neck Measuring 0
 
 

Measurement is accurate even if there is water and dust

Thanks to individual optical system and measurement algorithm, the measurement data of TL-2000S Series is still accurate at complex environment.
Environmental adaptability reaches to IP67.Besides,air filter is available to prevent lens front side from contamination ,ensuring measurement data is accurate at various extremely complex environment.
Flat Wire Single Axis Laser Micrometer Diameter Lump And Neck Measuring 1

Touch Screen,Computer,Cellphone

DALA TL-2025D can be managed by touch screen,computer and cellphone,like parameter setting ,measurement data management ,and so on,customers can choose as their application request.

Flat Wire Single Axis Laser Micrometer Diameter Lump And Neck Measuring 2

size

Flat Wire Single Axis Laser Micrometer Diameter Lump And Neck Measuring 3

Flat Wire Single Axis Laser Micrometer Diameter Lump And Neck Measuring 4

 

Technical Specification

 

Model TL-2006S TL-2025S
Axis 1-axis 1-axis
Sampling frequency 5KHz 10KHz
Measurement range 0.02~6mm 0.2~25mm
Repeatability ±0.03μm(1) ±0.1μm(2)
Measurement accuracy ±0.5μm(3) ±3μm(4)
Working power 24VDC ± 5%, Max. 30W
Application field Round wire ,Transparent wire, Flat wire
Measurement data Round wire, clear wire, flat wire,rod stock, tubing, etc.
Communication port Default:WIFI,RS485 MODBUS RTU,CAN
Option:PROFIBUS,PROFINET, EtherNet/IP EtherNet,etc.
Electrical port Default:Digital output (relay), Digital input,Analog input encoder pulse input port.
Option: PI feedback control(3)
Environmental  adaptability

Working Environment

0~50 ℃
Working Environment 20~85%RH(No condensation)
Working environmental brightness Brightness of working environment Incandescent light, fluorescent lamp 3000lx or less
Vibrating resistance 10~55Hz full amplitude 1.5mm in XYZ direction for 2 hours
Impact resistance 10G/6ms
Data colletion & analysis DMS1000 measurement software system,DS14 ZT display and control system
Out-of-tolerance alarm Support
Transparent mode Support
Water-proof grade IP67

 

NOTE:

(1)Set average time to 0.1s and measure the ±2σvalue of the φ1mm round rod at the measurement area center;

(2)Set average time to 0.1s and measure the ±2σvalue of the φ10mm round rod at the measurement area center;

(3)Move φ1mm round rod in the measurement area of 2*2mm and conduct measurement error;

(4)Move φ9mm round rod in the measurement area of8*8mm and conduct measurement error;Move φ18mm round rod in the measurement area of4*4mm and conduct measurement error;

 

Gelijksoortige producten
Stuur uw vraag
Stuur ons uw verzoek en wij zullen u zo snel mogelijk antwoorden.
Stuur